Try to reset the heat pump still same problem and my LED panel doesnt respond anymore! There are no diagnostics LEDs that flash. Looking for pool parts? I had to purchase a new display board and cover (the part that we see). So maybe they have been added to the retainers pool of item they can find. Might be a connection problem!! With a full line of pool products including pumps, filters, heaters, lights, valves, water sanitizers, and the automation solutions to control it all, Jandy has the complete pool equipment package for any pool or spa. VX65 iQ Control Box for Zodiac Robotic Cleaner Global Pool and Pump from globalpoolandpump.com.au. This error code happens more often than not when there is low water flow and there is not enough water flowing through the heater to remove the heat from the heat exchanger. https://i.imgur.com/ekjn2ut.jpg. Is the thermostat set too low? I have replace the ignitor but still have same problem and display. I have a Raypak gas heater. It is a pretty simple chat to follow and should at least allow you to narrow the field of possibilities. It could be the result of debris accumulating in the drive pulley. 0000003209 00000 n
If you try to change it, you might be able to solve the problem. We had a Jandy lxi installed mid-winter in our home in Northern California. You can buy equipment directly. Was told maybe the control board was bad ?,any thoughts. If it still is not working properly after you have done the above step, you should look for leaks in the hose.
Troubleshooting Jandy AquaPure Error Codes - Leslie's The 2nd is after modified the 3-port valve to the return lines. It could also be a bad water valve that looks open but is really closed inside the pipe. . Are there any other signs when the heater shuts down? My heater is giving me a code after about one minute of heating up. Zodiac Pool Systems United States | Zodiac Pool Systems MX8 Elite The first suction pool cleaner with Cyclonic Scrubbing Action! Any ideas on what the problem could be? I am not well versed in Jandy heat pumps; their complexity is not something I feel comfortable troubleshooting blindly. FAULTSHORTEDCOIL SENSOR-or-FAULTOPENCOIL SENSORIn the event that the coil temperature sensor malfunctions or is not connected the control will shut off the heat pump.FAULTSHORTEDWATER SENSOR-or-FAULT OPENWATER SENSORIn the event that the water temperature sensor malfunctions or is not connected the control will shut off the heat pump. If the supply valve is OFF, turn it ON. Smith Water Heater Parts; Baxi Water Heater Parts; Bradford White Water Heater Parts; The heater only comes on if its turned all the way up. You are using an out of date browser. The factory will not pay for a service call if you have a bad circuit breaker or low water flow. Same thing. Close water features, or alternate them, until the pool heats to the desired temperature. 26 Add To Cart Add to Compare Add to Wishlist Zodiac Valve Cap Z67395 11. Within 2 minutes, the yellow LED should stop blinking on the iAquaLink. Fill out a contact form to get a personalized response from our pool heating experts.
Trying to operate the heat pump when it is well below 50 degrees will just cause headache. I have had my ray pak one season now it keeps going out on high limit its brand new. Attempts to fire again. Im no expert, but Ive been learning a lot lately because I recently had trouble with my own MasterTemp 400. I ran it for a half hour and went to turn it on the next day and now nothing again. It kept doing this several times and then sometimes the temp will start counting up rapidly and slowly counts down to the current temp and cycles again. Have you tried cleaning the filter to see if that fixes any flow issues? Have not tried to jury rig a fix as I have the broken fitting. Make sure you have installed the temperature sensor correctly and it is in good condition. Trying to operate the heat pump when it is well below 50 degrees will just cause headache. Diagrammes D'coulement des Menus, Systme de Combinaison Piscine/Spa Menu Principal, Glossaire des Dlais Et des Verrouillages de Scurit, Seccin 1. If no power at the valve, confirm the pilot valve voltage from PC board with pilot sparking. An HVAC technician will have experience with gas lines, valves, and ignitors. I have a Hayward Easy Temp heater. . So the problem is likely to be gas supply or the flame sensing circuit. !To Purchase Parts in this video or a great replacement heater check out these Links !Jandy Laars Pressure switch: https://amzn.to/3zUk7VuJandy on/off Switch: https://amzn.to/3fNui74WARNINGPlumbing, venting, and gas hookup will need to be done with most Heater Replacements!Raypak 266,000 BTU millivolt pool heater (Make sure you order a 7 inch hood kit also if it is indoors) https://amzn.to/3g64UJCRaypak 266,000 btu digital Natural gas pool heater https://amzn.to/3DJRUUlRaypak 266,000 btu digital cupro-nickel (Propane) heater https://amzn.to/3DFO4f3Raypak 266,000 BTU 7 inch indoor hood kit https://amzn.to/3k0uJMiRaypak 206,000 BTU millivolt pool heater (Make sure you buy the 6 inch hood kit also if it is indoors) https://amzn.to/37RTmFfRaypak 206,00 BTU 6 inch indoor Hood kit https://amzn.to/3m31j2URaypak 406,000 BTU Cupro-nickel Digital control natural gas pool heater https://amzn.to/38ji0PyRaypak 399,000 BTU Digital Low NOx high elevation natural gas pool heater. I suggest contacting the manufacturer to see if they will do a guided troubleshoot over the phone. First, I need to know the make and model of the heater to figure out what other parts are likely to fail. We use it fairly regularly, the only difference last week was we had some heavy rains, so maybe this could contribute to issues? Zodiac LRZM LRZE Outdoor Vent Cap 400BTU | R0491605 Quantity: $196.10 36 Jandy Legacy Indoor Drafthood Kit LRZ Model Heaters 400K BTU | R0499605 Quantity: $225.79 37 Jandy LRZ Heater Adapter Plate 400K BTU LRZM LRZE | R0478305 Quantity: $23.30 38 R0500200 LRZM LRZE CLIP AllBTU Quantity: $19.88 39 Is the gas supply valve in the ON position?
When it comes to troubleshooting, the weather is important. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. Are there any diagnostic LEDs lit or flashing?
Pool Heater not turning on: Jandy Pool Heater Tips and - YouTube Build the perfect swimming pool environment with Jandy professional-grade swimming pool equipment.
I receive a message "Fault Shorted H2O Sensor" what does that All display functions seemed to operating normally (temperature read out was good, i was able to cycle the mode from standby, to spa, to pool, and back to standby). This . 0000001391 00000 n
Parts4heating.com: Zodiac Pool Heater Troubleshooting Guides Pool Research: Advice, Reviews & Data on Swimming Pools She walks in standard school shoes with light blue calf-length socks. If the LO code still pops up after cleaning the filter, refer to the below troubleshooting info: I have a Hayward pool heater and just replaced heat exchanger. Next Day Delivery Service does not mean Next Day Air, but simply that your qualifying products will be shipped from the warehouse closest to you resulting in delivery the next day. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. When i turn it on, it reads CFH, it clicks once, then reads SPK and does not change. If this is the case, it is time to replace it. Make sure it is higher than the actual pool water!Low Freon pressure.This error code happens most when it is too cool outside to heat. No cracks. Check to see if the return line fittings are pointed down. All wire were put back as they were.
Global Pool And Pump - GLOBKAL My previous heater lasted 20 years. Instrucciones Importantes de Seguridad, Seccin 2. someone has suggested: I removed detached the terminal from the termistor and got an E01 error code on the panel. What should I be looking for? Will fire up to prevent freezing when water temperature is a (settable) 36~40 degrees. We are a registered 501(c)3 non-profit that is funded by user donations. With expansive product lines, Zodiac can deliver the most technologically-advanced, energy-efficient, durable and reliable products available which include . Pentair 520540 EasyTouch 8 Pool/Spa Control System, Base System - No ICP, 2 Actuators,Almond 3. If so, then the proving signal is not getting back to the PC Board. You will get much more visibility by. no leaking going on at all. Almost all heaters now use flame sensing to keep the burner lit. Search by Product Name or Search Product List Pool Heaters Pool Cleaners
Zodiac Pool Systems United States | Zodiac Pool Systems To avoid personal injury when working with pool chemicals, always wear rubber gloves and eye protection and work in a well-ventilated area. It will turn on and turn back off after about 45 seconds. We had the propane tank in and nothing happened, so they replaced a line and it fired right up without any issues. Apple is not a participant or sponsor of this promotion. Low ambient air temperature. Water has always been in tip top shape. Front board power supply either too low or too high.
Pool Heater Won T IgniteIf you have a gas heater that won't light, then Any new postings here are unlikely to be seen or responded to by other members. POOL HEAT Zodiac POOL HEAT Zodiac Enabled 12:40PM Enabled. Is the heater hooked up to an automated control or is it standalone? Solution: First, look for any coils or tangles in the hose. It does an excellent job and is dependable, but if you encounter a problem, make sure you can quickly resolve it. Copyright 2023 Dohenys . Firstly, check your pump lid, which may be loose. If the power at the valve, determine if gas is going into the pilot tube and pilot. I have replaced the Stack sensor thinking that it was the problem.
Zodiac Robotic Pool Cleaner Troubleshooting Guide Diagrammes D'coulement Des Menus, Page 52: Systme Piscine Seulement Menu Principal, Page 60: Seccin 1. The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on.
Customer Support: We're Here For You | Jandy SYMPTOM CORRECTIVE ACTION Heat pump will not start, no control board display. The return line fittings may also be pointing in the wrong way. By submitting your email address, you agree to receive email communications and other great offers from Zodiac Pool Systems LLC Subscribe. * Plus, get tools and education from Pentair to help you know and manage the water in your home. So I thought that was causing the problem. The switch to the heater is on. We offer great everyday prices, but If you see it for less, we will match that price! 2 hours later got a Error Code E08. We have thousands of items eligible for next day shipping! Everything works fine until after about 15 min, when the fan just blows cool air and there is no flame anymore. Also for: Legacy lrz millivolt. 0000001816 00000 n
Raw chlorine is a commodity making chlorine tablets is an art form. Consignes de Scurit Importantes, Rchauffeur de la Piscine ACTIV/DSACTIV, Activer/Dsactiver Manuellement un quipement Spcifique, Section 4. Pumps need to be air-tight to operate - any leak will cause your pump to suck air. I removed the front panel and I see the wiring and boards in there. 0000008392 00000 n
For our example heater, we will be using the Old Teledyne Laars Series I & Series II Spark Ignition heaters, made from 1986-1997; but the concepts apply to electronic heaters made by Raypak, Hayward or Purex - RP2100, H-Series or Minimax Plus heaters. If no power, replace the board. Pool Elementary goes over the basics of the simple causes of a Jandy and Teledyne Laars milivolt or Pilot Light Swimming Pool Heater not starting up or firing. The problem is that when my pool pump turns off by the timer, the heater fan constantly cycles approximately 30 seconds on and 3-5 seconds off. It could be a header gasket that is causing the leak. I have a Jandy model LT4000N-LB pool heater. Parts4heating.com: Zodiac Pool Heater Troubleshooting Guides. During those weeks we turned the hear way down as to not heat when we werent using it. Broken igniter. the pool place thinks it might be putting copper into my pool. CALL 800-536-1582. For the best experience on our site, be sure to turn on Javascript in your browser. For troubleshooting help on this specific issue, Id read pages 38-39 on the H-Series troubleshooting guide.
Zodiac g4 pool cleaner manual - Australia Manuals Working Examples Solution: Check if the hose has become brittle. If there is no gas coming from the energized pilot valve, replace valve. Departments Accessories . The store will not work correctly in the case when cookies are disabled. 550 SETI Air Energy Super Heater Heat Pump AE 1000 Heat Pump AE-Ti Heat Pump It doesnt sound like you have enough water flow.
Amazon.com : Zodiac R0458100 Power Distribution Circuit Board The heater works the SHUTS off given a LO ERROR. Heater will turn on automatically as Aux2 long as the filter pump is on and the water temperature is below the temperature set point. (Generates 173 - Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. personal injury, or death. FREE SHIPPING on Orders $100+. Please consider. How long after the flame goes out does the blower run? To successfully troubleshoot all kinds of pool heater issues, you will need a flathead screwdriver, safety eyewear, a Phillips screwdriver, a pipe wrench, an adjustable wrench, a pair of gloves, a 3/16" Hex key, channel locks, a digital differential manometer, a tape measure, a voltage meter, a PVC pipe cutter, and a power drill. 0000001964 00000 n
Make sure to keep your valves open as to not prevent the water flow. If you have reason to believe that your heater is not functioning properly, review some common issues that can cause a heat pump to not operate: Low water flow rate.This is the number one issue for the heat pump not working. Leak stopped. I have a H200 gas heater. No flame at burners. 2012 - However, it isnt ALWAYS the case. It clicks, but will not light. My name is Ron Walsh. Were you able to troubleshoot the problem?? We have documented the powerful features of our products, and how to use them, so that you can maintain your pool with ease.
Zodiac Pool Heater Parts - Buy Zodiac Pool Heater Repair Parts Online How are you judging the strength of this water flow? Do you think a new thermal regulator might be the answer? Ensure thepump basket and lid are in good conditions.
Zodiac Pool Cleaner Troubleshooting - Full Guide If the heater is cycling on and off but there are no error codes or error lights on the back of the control module you need someone onsite to inspect the heater. Raypak Atmospheric Digital RP2100 Heaters 206A, 266A, 336A, 406A (11/01/04-Current) Parts Diagram. If not, point them in the right direction. All indicator lights go out and nothing I do makes them light up. Troubleshooting Guide for Jandy Heat Pumps Jandy-Zodiac Technical Support: 800-822-7933 The following provides symptoms and solutions for general troubleshooting problems for Jandy heat pumps. I changed out my pressure switch that came apart and removed the NO Flow code and now I have this one. If the supply valve is OFF, turn it ON. I had a pool guy out to look at it due to this issue a month ago. So, whats the best way to fix it properly? Pool Mode enables the filter pump to circulate water through the filter and pool heater. Is the pilot lighting? I have a Pentair Master Temp 300 Pool Heater that is 6 years old. If there is no reaction then it is rain or condensation water. Use our interactive diagrams, accessories, and expert repair help to fix your Zodiac Heater . 5 For sale near youMatching RVs for sale near you $0 $0 $0 $0 Top 10 RVs Voted most helpful review Kenneth H RV reviewed 2016 Jayco Jay Flight SLX 195RB 4. The code that appears on the display says Check IGN Steps and then shuts down. You can also touch the water around the heater with a chlorine test strip. If theres someone to learn about above ground pools, pool cleaners and maintenance from, it would definitely be me.
Owner Manuals - Pool Heating Systems There could be a defect in the heat exchanger caused by the manufacturing process or imbalanced water chemistry. Posted: October 25, 2017. A digital thermostat control gives you the ability to adjust the target temperature quickly and precisely. I have a Hayward Titanium Heat pro model HP21104t model heat pump. Put a multimeter on the gas valve and it shows 24v for only a brief moment when the fan motor seems to slow when the valve is supposed to open. If your thinking about replacing your old unit or making the best step in purchasing one, this robot will save you tonnes of time, keeps your pool pristine and the warranty is exceptional as well. Do I have to take it apart to check the heat exchanger ? For the best experience on our site, be sure to turn on Javascript in your browser.
Maytronics Dolphin Active X6 | ProductReview.com.au Does it not work on especially warm or cold days? For in-depth information and instructions for your Zodiac product, search or navigate through the Equipment Assistance library below. And then you must place it around number two.
Solution: All you have to do is not to keep the cable out when the temperature drops below 70 degrees Fahrenheit. You need to check the connection of the NET and NET 1 cables. I also noticed that the flap wasnt opening even at 3450rpm and 20-25psi.
Later located the water temperature sensor. Pool Research: Advice, Reviews & Data on Swimming Pools Does it not restart after its been in heavy use? The first thing you should do if your Zodiac pool cleaner stops and starts is to check the suction flow coming through the hose. Now this happens now and then since I bought the unit. Pentair MasterTemp Low NOx Pool Heater, Electronic Ignition, Natural Gas - 200,000 BTU, 460730 (PUR-15-0730), 788379724054 Shop online or in-store in Derry, NH, Plaistow, NH, or North Reading, MA for pool and spa supplies, above ground pools, spas, parts and accessories. What - Answered by a verified Pool and Spa Expert. My pool heater zodiac LRZ 400 is not lighting I have replaced the ignitor limit switches and flame sensor. I only found 1 small stone stuck inside where the bypass is. I have a Raypak RP2100 heater. Global swimming pool pump market size was ** billion usd in 2021, and will expand at a cagr of **% from 2022 to .
Heater Trouble Zodiac lxi 400N Fault | Trouble Free Pool Poor water chemistry is one of the leading causes of equipment failure, especially pool heaters. I have a Hayward pool heater (model #H250FDN). SEARCH.
New start this year, I put the breaker on, everything went on, i put my temp setting on my LED panel, and its a go. Pool Heater Replacement Parts. Pool and Spa Heater Natural Gas or LPG. With my love of water, and pools in particular, it was only natural that I follow a career path in the swimming pool industry. Whether through best-in-class products, or through industry-leading dealer loyalty program, Zodiac is the provider of choice for millions of people worldwide. 2020 Zodiac Pool Systems LLC - All rights reserved. My igniiton clicks, but then it fails to heat pas this point, sigh. Then when he left the heater started working! Needless to say, I learned to love water at a young age. Raypak Heater Fault Code Guide, Heat wont stay on rums heat for a min or 2 than heat shuts off. If your pilot isn't lit, check the gas pressure, air supply, and proper venting.
Equipment Assistance | Product Manual | Zodiac Australia When I fire up the heater on Pool mode it begins to heat normally but after about 5-10 minutes (and even sometimes after 20 minutes) it moves over to Spa Heat mode (which I dont have a spa) and shuts down the heater. Register Product Warranty Policy
Best Pool Heaters Of March 2023 - Forbes Home Aquabot S2 50 Review Why its best for above ground only? Thank you. Power pack must not be installed directly above any other heat source such as filter, pump or heater. I have a Hayward H100ID. I agree. I am a new pool owner and am frustrated with our brand new Jandy LXi gas heater. 1st one is the initial issue. Rio Bravo, Inc. Low gas supply pressure. You will need a licensed electrician to tell you for sure. Our customer service team is available Monday through Friday, 8am - 4pm EST. The unit is covered in ice. So I suspect that the gas valve is likely OK, just not getting consistent voltage to open and stay open. Avoid this type of weather since it will cause the cable to tangle. Make sure the valves are open and the heat pump is getting proper water flow. Days later, theyre suddenly working again. This applies to products even if they do not have a Next Day Delivery designation. Is there a common thread between the times it does/doesnt work? Your email address will not be published. So, I opened the 3-port valve and adjusted it where the 2 return lines are fully open. So I opened up our Jandy Legacy LRZ 399,000 to replace the insulation panels. Any thoughts? install, service or troubleshoot this C Series Chlorinator. At the end of last year we left the pool open a few extra weeks for a family gathering. At the very least, acquire some sun and extend the amount of time you lie the cable in the sun, then observe how it works to untangle the knots. The cool weather will not soften the hose and cable. Doheny's DIY Pool Care Help Center.
Pool Supply Unlimited | Jandy Legacy LRZ Pool Heater | 400,000 BTU 0000005042 00000 n
ZODIAC AQUALINK Z4 OWNER'S MANUAL Pdf Download | ManualsLib I have a Pentair Heater. 0000010002 00000 n
do i have to change my LED panel or the board itself inside?? Theres a lot of videos out there about it. This is something you should do around the house. IO Igniter open error If the control is not in lockout and senses that the igniter circuit is open when the blower is running the control will turn off the blower and go into lockout. the heat pump must be installed at a minimum distance of 3.5m from the edge of the pool in order to avoid any projections of spray onto the appliance. JavaScript is disabled. Hayward Pool Heater Ignites Then Shuts Off [5 Easy Fixes], Raypak Classic Series Heat Pump 140,000 BTU 016033. Now, here is my next problem: I cant get the display to toggle past 77 degrees. I clean the filter. 2012 - Have you checked the circuit feeding the heater to make sure it is providing the proper voltage? If your heater is undersized, it will have problems heating your pool up. This weekend, when I finally had time to work on it, I see there is no power to the display at all: no service light, no heater light, no light or display of any kind. The compressor does not engage, just the fan. https://amzn.to/3krxdnj $3000 for a heater and now annual service calls? This item: Zodiac R0457501 Hot Surface Ignitor Replacement for Zodiac Jandy Legacy LRZE Pool and Spa Heaters $216.46 Zodiac R0012200 Fusible Link Assembly Replacement Kit for Select Zodiac Jandy Pool and Spa Heaters $8.90 Wholesale Sensors Replacement for Jandy/Zodiac R0456500 Temp Sensor for Spa 12 Month Warranty $18.49 Compare with similar items Is the water to temp when the pump shuts off? Solution: To troubleshoot the problem, make sure there is enough hose length to support the devices operation. trailer
<]>>
startxref
0
%%EOF
102 0 obj
<>stream
Reset breaker or check fuse. Orifices were clean. There are other factors that can actively contribute to your heaters ON and OFF cycles. No service system or service heater lights. A.O. This could be as simple as your filter was dirty, which constricted flow to the heater, or you would have to troubleshoot the various switches. Only 5 months old is leaking out the bottom. Browse all Zodiac product, troubleshooting, and installation videos. I have a Pentair mini max 100 heater hooked up to a cedar hot tub. Dohenys Pool Supplies Fast has Free Shipping on orders over $100! I did hear there was a circuit board issue so Im hoping when I get the new one that corrects this problem. No error codes. I suspect maybe its the flame sensor? Verify cold air is blowing out the top of the heat pump. Instrucciones Importantes De Seguridad, Page 63: Seccin 2. xb```b``vf`e``-ed@ AGCXARLr5k\q=6/I 13vytBH
_dX^cR 2fNc bh:5g{H _SE[>1E2d|SEmfntzcX`lN&G `Q]zS0h`'kGe3$jYD&b wmS\Iq{-;#`T]t{DG*h;0()u@E0**(g`R23 4aj9PaK(
,iiiu
$)X2pzK ia V[#taZDB5BK\Vrs!+ 1HGf0e#{A-8= %*
endstream
endobj
82 0 obj
<>/Metadata 79 0 R/Pages 75 0 R/Type/Catalog>>
endobj
83 0 obj
<>/ColorSpace<>/Font<>/ProcSet[/PDF/Text/ImageB]/ExtGState<>>>/Type/Page>>
endobj
84 0 obj
[/ICCBased 98 0 R]
endobj
85 0 obj
<>
endobj
86 0 obj
<>stream
The Heat light blinks calling for heat and then it ignites Heat light goes steady for a few seconds and then stops and calls for heat again (Heat light blinks) and then ignites, Heat light steady and then stops again. 0000011890 00000 n
I agree to receive emails from Zodiac and its subsidiaries related to products and services.
Product Manuals | iAquaLink This Power Distribution Circuit Board Is Designed To Use With Zodiac Janay Lexi Low NOx Pool And Spa Heater Models 250, 300, 400 ; Power Distribution Circuit Board Replacement ; Fits Zodiac Janay Lexi Low NOx Pool And Spa Heater Models 250, 300, 400 ; Country Of Origin: United States Other then the inaccurate temp the heater works fine, Are there any codes being flashed on the screen? Toggle the breaker switch to see if any of them is short-circuited. Is this is a common problem?? Without gas, the heater wont operate. Web connect device for use with aqualink rs for systems with rev r firmware or later for use with pda for systems with 6.0 firmware or later (16 pages), Web connect device for rs & pda control systems (68 pages), Manual will be automatically added to "My Manuals", Section 1. For example, in some cases, you will see a Low Water Flow warning pop up on your heaters LCD screen. For MV heaters, if the pilot wont stay lit, check the output on the thermocouple.
Jandy Pool Heat Pump Troubleshooting Guide Pentair Heater Burner Troubleshooting: The burners on this type of . A dirty filter can prevent a heater from firing and it can also cause your heater to shut off before warming the water to the desired temperature. Fill out a contact form to get a personalized response from our pool heating experts. Ensure that the power outlet you are using with the machine is functioning properly. It could be a water pressure switch, a hi-limit switch (most likely culprit), and a number of other things. 0000020514 00000 n
Pool Heater & Heat Pumps: Pool Heating Systems | Jandy I have a MasterTemp 200. Your pool pump only moves a certain number of GPMs, therefore, too many water features can dramatically decrease your water flow. Dohenys. Hi, 2023 Poolheatpumps.com. Corporate; Support; Find a Dealer . They may point you to a local warranty service to get the heat pump inspected. This page is powered by a knowledgeable community that helps you make an informed decision. Heater is one year old. Click here to shop our store. Dolphin Oasis Z5i Review What Users Saying About it? Call us at (800) 536-1582, email helpdesk@parts4heating.com or live chat with a member of our team here on our website to begin exploring options for Zodiac pool heater parts. - Program up to 49 on/off event settings per day. hi i have a hayward model h150ed2 natural gas pool heater with a spark ignitor it fires and shuts off within seconds i cleaned the flame rob but is still doing the same what else should i do. Pentair Easytouch EasyTouch systems are available for a separate spa, a separate pool, or a pool/spa combination with shared equipment. Rio Bravo, Inc. the instructions in this manual can be followed exactly. If it still doesn't work, use the flow tester to make sure the cleaner is getting enough water.